Incubator KB series

Refrigerated incubators with individual programming options, real-time function, and a broad temperature range.

KB 400 (E3.1) (14.1 cu.ft.)

The KB is the all-rounder for microorganisms. With its wide range of individual programming functions, including a real-time clock function and an enormous temperature span, it can be used for a broad range of sophisticated applications in laboratories – with minimal dehumidification of specimens and impressive extra performance. The APT.line™ with its electronically controlled preheating chamber ensures rapid recovery times and maximum precision, unaffected by the ambient temperature.


Reliable incubation, Disinfection routine at 100 °C, Broad rande of applications

KB 400
Applications
  • Microbiological tests with open containers

  • Microbiological tests with closed containers

  • Food microbiological tests

  • Mixed sample testing

Application Areas
  • Food & Beverage Industry
  • Nutritional Medicine
  • Biotech & Pharmaceutical
  • Hospital & Health Care
  • Research institutes & university
  • Microbiological laboratory
  • Quality assurance
  • Laboratories for production
  • Tissue culture engineering
Unique features
  • Electronically controlled APT.line™ preheating chamber assuring temperature accuracy and reproducible results
  • High quality standard, 27-point measurement pursuant to DIN 12880
  • Disinfection routine at 100 °C (212 °F)
  • Large reserve capacity thanks to BINDER cooling technology (KB series)
  • Electronically controlled APT.line™ preheating chamber and patented DCT™ refrigeration system assuring temperature accuracy and reproducible results in both heating and cooling situations
  • Temperature range: -5 °C to 100 °C (23 °F to 212 °F)
  • MP controller with 2 programs with 10 sections each, alternatively switchable to 1 program with 20 sections
  • Features:
    • Integrated week program timer with real time function
    • Adjustable ramp function via program editor
    • Digital temperature setting with an accuracy of a tenth of a degree
    • Adjustable fan speed
    • Elapsed time indicator
  • Independent adjustable temperature safety device class 3.1, providing full protection against chamber over-temperature, with visual and audible temperature alarm
  • Inner glass door
  • RS 422 interface for communication software APT-COM™ DataControlSystem, or switch over to printer output with RS 232 / RS 422 interface converter
  • Adjustable intervals for printer
  • 2 stainless steel racks
  • BINDER test certificate
KB 400 (E3.1)
Exterior dimensions
Width (mm/inch) 884 / 34.8
Height (inclusive feet) (mm/inch) 1850 / 72.8
Depth (mm/inch) 716 / 28.2
Plus door handle, I-panel, connection (mm/inch) 100 / 3.9
Wall clearance (mm/inch) 100 / 3.9
Wall clearance with open door(s) (mm/inch) 160 / 6.3
Steam space volume (l/cu.ft.) 515 / 18.2
Number of doors 1
Number of inner glass doors 1
 
Interior dimensions
Width (mm/inch) 650 / 25.6
Height (mm/inch) 1308 / 51.5
Depth (mm/inch) 470 / 18.5
Interior volume (l/cu.ft.) 400 / 14.1
Racks (number standard/max.) 2 / 15
Load per rack (kg/lbs.) 20 / 44
Permitted total load (kg/lbs.) 50 / 110
Weight (empty) (kg/lbs.) 216 / 477
 
Temperature data
Temperature range (°C/°F) 1) -5 - 100 / 23-212
Temperature variation
at 5 °C (41 °F) (± °C) 0.6
at 25 °C (77 °F) (± °C) 0.3
at 40 °C (104 °F) (± °C) 0.3
Temperature fluctuation
at 5 °C (41 °F) (± °C) 0.1
at 40 °C (104°F) (± °C) 0.1
Heating up time to 40 °C (104 °F) (Min.) 2) 10
Cooling down time from 40 °C (104 °F) to 5 °C (41 °F) (Min.) 2) 96
Recovery time after door was open for 30 sec
at 5 °C (41 °F) (Min.) 6
at 40 °C (104 °F) (Min.) 1
 
Electrical data
Housing protection acc. to EN 60529 IP 20
Nominal voltage (±10 %) 50/60 Hz (V) 230
Nominal voltage (±10 %) 60 Hz (V) 115
Nominal power (kW) 1.1
Energy consumption 3)
at 5 °C (41 °F) (W) 450
at 40 °C (104 °F) (W) 120

Based on the ice increase on the evaporators the refrigerating capacity decreases at a set value of < 0 °C (32 °F).
For this reason the chambers have to be defrosted regularly (approx. once a week).

1) at an ambient temperature ≤20 °C
2) up to 98 % of the set value
3) these values can be used upon calculation of air conditioning systems

All technical data are specified for units with standard equipment at an ambient temperature of  25 °C and a voltage fluctuation of ±10 %. The temperature data are determinated in accordance to factory standard following DIN 12880 respecting the recommended wall clearances of 10 % of the height, width and depth of the inner chamber. All indications are average values, typical for units produced in series. We reserve the right to alter technical specifications at all times.

  • Waterproof interior socket

    Switchable waterproof interior socket 230 V AC (max. 200 W), IP65 protected, with corresponding plug. Max. allowed operating temperature 50 °C (122 °F).

  • Additional PT 100 temperature sensor

    In situ or flexible installation for exact temperature measurement within the specimen material; connects to a special plug on the back wall of the inner chamber.

  • Calibration certificates and validation

    BINDER can significantly reduce the time and effort needed for equipment qualification and validation. We draw on unparalleled knowledge of our equipment applications and years of experience in certification.

  • BINDER Data Logger kits

    The new BINDER Data Logger kits for temperature can record temperature data of BINDER equipment. This finely tuned product solution also contains useful accessories for mounting the Logger on the BINDER unit, including cable bushings and a sensor mounting bracket.

  • Operational data documentation: APT-COM™ DataControlSystem

    The only standard software that guarantees seamless documentation of all testing parameters in compliance with standards. Can be fully validated in accordance with GLP/GMP and FDA 21 CFR Part 11.

KB 400 (E3.1)
Access port with silicone plugs, 10 mm (0.39 inch), 30 mm (1.18 inch), 50 mm (1.97 inch), 100 mm (3.94 inch) O
Factory calibration certificate. Measurement in center of chamber at 37 °C (98.6 °F) or at specified testing temperature O
Extension to factory calibration certificate. Each additional measurement at an additional measuring point or temperature O
Temperature measurement acc. to DIN 12880 (27 measuring points) at 37 °C (98.6 °F) or at specified temperature with measuring protocol and certificate O
Securing elements for additional fastening of racks (1 set of 4 pieces) O
Anti-slip rubber pads for safe stacking (1 set of 4 pieces) O
Data Logger Kit T 220: For the continuous temperature recording of -90 °C (-130 °F) to 220 °C (428 °F). Kit includes 1 data logger, PT 100 sensor with 2 m Teflon extension cable and 1 fixture for the connection at the BINDER unit O
Data Logger Software: Configuration und evaluation software for all BINDER Data Logger Kits, incl. data cable O
Zero-voltage relay outputs accessible via 6-pin DIN socket. Additional module for controlling 2 relay outputs via 2 of the programmable controller’s controller contacts. Outputs can be switched on and off program-controlled either automatically, or also manually O
Switchable waterproof interior socket 230 V AC (max. 200 W), IP65 protected, with corresponding plug. Max. allowed operating temperature 50 °C (122 °F) O
Additional PT 100 temperature sensor, flexibly installed, with external connection, including LEMO connector (3-pin) O
Analog temperature output, 4-20 mA, with 6-pin DIN socket (output not adjustable) O
Rack, stainless steel O
Shelf, perforated, stainless steel O
Fixed shelf (positioned at bottom level), with additional fixtures to enable shaker operation. Other positions available on request O
Door lock O
Temperature safety device, class 3.3 (DIN 12880) with visual alarm O
Interior lighting (30 W) O
Application / Industry

Find the ultimate incubator that best meets your specific requirements…

Choose your Coupon

Limited offer until December 31st 2012. Reserve you free special now!

Datasheet KB 400 (E3.1)